CONTACT US
sales@gromyscale.cn
|
L6T
 Load cell L6T
|
◆L6T load cells are available in the capacities 50kg to 1000kg.
◆Alumium construction with parallel beam.
◆Silicon adhesive sealed, surface anodized
and anti-corrosion.
◆Intergral structure and easy installation.
◆Suitable for electronic platform scales, electronic pricing
scales and other electronic weighing devices. |
Features
◆Capacity:50kg to 1000kg .
◆High accuracy.
◆Max. platform size:
600x600mm. |
Specifications
|
Capacity |
(kg) |
50/75/100/150/200/250/300/500/635/1000 |
|
Accuracy |
|
C3D |
C3 |
C3G |
|
Approvals |
|
|
OIML R60 C3 |
|
Maximum number of
verification intervals |
n max |
2500 |
3000 |
4000 |
|
Minimum load cell verification interval |
v min |
Emax/5000 |
Emax/7000 |
Emax/11000 |
|
Combined error |
(%FS) |
≤±0.030 |
≤±0.020 |
≤±0.015 |
|
Creep |
(%FS/30min) |
≤±0.020 |
≤±0.0167 |
≤±0.0125 |
|
Temperature effect on sensitivity |
(%FS/10℃) |
≤±0.021 |
≤±0.0175 |
≤±0.0131 |
|
Temperature effect on zero |
(%FS/10℃) |
≤±0.028 |
≤±0.020 |
≤±0.0127 |
|
Output sensitivity |
(mv/v) |
2.0±0.2 |
|
Input resistance |
(Ω) |
406±6 |
|
Output resistance |
(Ω) |
350±3 |
|
Insulation resistance |
(MΩ) |
≥5000(50VDC) |
|
Zero balance |
(%FS) |
2 |
|
Temperature,compensated |
(℃) |
-10~+40 |
|
Temperature,operating |
(℃) |
-35~+65 |
|
Excitation, Recommended |
(V) |
5~12(DC) |
|
Excitation,Max |
(V) |
18(DC) |
|
Safe overload |
(%FS) |
150 |
|
Ultimate overload |
(%FS) |
300 |
|
Corner correction |
|
0.02% load value/100mm |
|
|
|